sqtsqt 发表于 2018-7-28 09:41:14

Juniper QFX5100交换机et接口input error及CRC/Align errors-CJcom

  故障现象:Juniper QFX5100-24Q通过监控发现et-0/0/2上出现Error包。
  通过命令:show interfaces et-0/0/2 extensive,显示input error以及CRC错误。
  状态显示:
  Physical interface: et-0/0/2, Enabled, Physical link is Up
  Interface index: 942, SNMP ifIndex: 516, Generation: 676
  Link-level type: Ethernet, MTU: 1514, Speed: 40Gbps, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled, Flow control: Disabled, Media type: Fiber
  Device flags   : Present Running
  Interface flags: SNMP-Traps Internal: 0x4000
  Link flags   : None
  Input errors:
  Errors: 771731, Drops: 0, Framing errors: 771415, Runts: 0, Policed discards: 0, L3 incompletes: 0, L2 channel errors: 0, L2 mismatch timeouts: 0, FIFO errors: 0, Resource errors: 0
  Output errors:
  Carrier transitions: 3, Errors: 0, Drops: 0, Collisions: 0, Aged packets: 0, FIFO errors: 0, HS link CRC errors: 0, MTU errors: 0, Resource errors: 0
  …………………………
  MAC statistics:                      Receive         Transmit
  Total octets               1216533781969    1073277356863
  Total packets                   1669078594       1462519491
  Unicast packets               1633851744       1398747806
  Broadcast packets                   361455         27733729
  Multicast packets               34865395         36037956
  CRC/Align errors                  771415                0
  FIFO errors                              0                0
  初步排查,影响的原因有可能是以下几点:
  1. 接口模块
  2. 光线或网线
  3. 两边接口是否全双工
  解决办法:
  经换模块,CRC显示正常,input error恢复正常。 开Case,对模块进行RMA处理。